Gas Boosters to 300 bar (4,350psi)
Note : pA = Gas Inlet pressure / pL = Air drive pressure / pB = Gas Outlet pressure
Model | DLE 15-1-GG | DLE 15-GG | DLE 5-15-GG | DLE 15-1-2-GG | DLE 15-2-GG | DLE 5-15-2-GG | DLE 30-1-GG |
---|---|---|---|---|---|---|---|
Model On Mobile Devices Scroll>>> | |||||||
Pressure Ratio | 1:15 | 1:15 | 1:5 / 1:15 | 1:30 | 1:30 | 1:10 / 1:30 | 1:30 |
Max Compression Ratio | 1:20 | 1:20 | 1:45 | 1:20 | 1:20 | 1:45 | 1:20 |
Stage Ratio | - | - | 1:3 | - | - | 1:3 | - |
Min Gas Inlet Pressure pA in bar (psi) | 7 (101) | 7 (101) | 2 (29) | 10(145) | 10 (145) | 2 (29) | 15 (217) |
Max Gas Inlet Pressure pA in bar (psi) | 150 (2,175) | 300 (4,350) | 300 (4,350) | 300 (4,350) | 300 (4,350) | 300 (4,350) | 300 (4,350) |
Max Permitted Outlet Pressure pB in bar (psi) | 150 (2,175) | 300 (4,350) | 300 (4,350) | 300 (4,350) | 300 (4,350) | 300 (4,350) | 300 (4,350) |
Formula To Calculate Gas Outlet Pressure pB | 15 x pL | 15 x pL + pA | 5 x pL + 3 x pA | 30 x pL | 30 X pL + pA | 30 X pL + 3 X pA | 30 X pL |
Displacement Volume In cm3 (ins3) | 122 (7.44) | 244 (14.88) | 373 (22.76) | 122 (7.44) | 244 (14.88) | 373 (22.76) | 60(3.66) |
Air Drive pA In bar (psi) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) |
Air Consumption In L/min | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) |
Gas Inlet Connection | 1/4 BSP | 1/4 BSP | 1/2 BSP | 1/4 BSP | 1/4 BSP | 1/2 BSP | 1/4 BSP |
Gas Outlet Connection | 1/4 BSP | 1/4 BSP | 1/4 BSP | 1/4 BSP | 1/4 BSP | 1/4 BSP | 1/4 BSP |
Air Drive Connection | 3/4 BSP | 3/4 BSP | 3/4 BSP | 3/4 BSP | 3/4 BSP | 3/4 BSP | 3/4 BSP |
Net Weight (kg) | 13 | 18 | 19 | 20 | 23 | 24 | 13 |