Gas Boosters to 600 bar (8,700psi)

Note : pA = Gas Inlet pressure / pL = Air drive pressure / pB = Gas Outlet pressure
ModelDLE 30-GGDLE 5-30-GGDLE 15-30-GGDLE 30-1-2-GG
Model
Pressure Ratio1:301:5 / 1:301:5 / 1:301:60
Max Compression Ratio1:201:901:401:20
Stage Ratio-1:61:2-
Min Gas Inlet Pressure pA in bar (psi)15 (217)2 (29)7 (101)20(290)
Max Gas Inlet Pressure pA in bar (psi)600 (8,700)2 x pL15 x pL600 (8,700)
Max Permitted Outlet Pressure pB in bar (psi)600 (8,700)600 (8,700)600 (8,700)600 (8,700)
Formula To Calculate Gas Outlet Pressure pB30 x pL + pA30 x pL + 6 x pA30 x pL + 2 x pA60 x pL
Displacement Volume In cm3 (ins3)110 (6.71)373 (22.76)122 (7.44)60 (3.66)
Air Drive pA In bar (psi)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)
Air Consumption In L/min400-1,980 (14.1– 69.9)400-1,980 (14.1– 69.9)400-1,980 (14.1– 69.9)600-2,400 (21.2-84.8)
Gas Inlet Connection1/4 BSP1/2 BSP1/4 BSP1/4 BSP
Gas Outlet Connection1/4 BSP1/4 BSP1/4 BSP1/4 BSP
Air Drive Connection3/4 BSP3/4 BSP3/4 BSP3/4 BSP
Net Weight (kg)18191920
ModelDLE 30-2-GGDLE 5-30-2-GGDLE 15-30-2-GGDLE 75-1-GG
Model
Pressure Ratio1:601:10 / 1:601:30 / 1:601:75
Max Compression Ratio1:201:901:401:20
Stage Ratio-1:61:2-
Min Gas Inlet Pressure pA in bar (psi)20 (290)2 (29)7 (101)35 (507)
Max Gas Inlet Pressure pA in bar (psi)600 (8,700)4 x pL30 x pL750 (10,875)
Max Permitted Outlet Pressure pB in bar (psi)600 (8,700)600 (8,700)600 (8,700)750 (10,875)
Formula To Calculate Gas Outlet Pressure pB60 X pL + pA60 X pL + 6 x pA60 X pL + 2 x pA75 X pL
Displacement Volume In cm3 (ins3)120 (7.32)373 (22.76)122 (7.44)25 (1.52)
Air Drive pA In bar (psi)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)
Air Consumption In L/min600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)400-1,980 (14.1– 69.9)
Gas Inlet Connection1/4 BSP1/2 BSP1/4 BSP1/4 BSP
Gas Outlet Connection1/4 BSP1/4 BSP1/4 BSP1/4 BSP
Air Drive Connection3/4 BSP3/4 BSP3/4 BSP3/4 BSP
Net Weight (kg)23242413