Gas Boosters to 2,400 bar (36,000psi)
Note : pA = Gas Inlet pressure / pL = Air drive pressure / pB = Gas Outlet pressure
Model | DLE 75-GG | DLE 15-75-GG | DLE 30-75-GG | DLE 75-1-2-GG |
---|---|---|---|---|
Model | ![]() | ![]() | ![]() | ![]() |
Pressure Ratio | 1:75 | 1:15 / 1:75 | 1:30 / 1:75 | 1:150 |
Max Compression Ratio | 1:20 | 1:100 | 1:50 | 1:20 |
Stage Ratio | - | 1:5 | 1:2.5 | - |
Min Gas Inlet Pressure pA in bar (psi) | 35 (507) | 7 (101) | 15 (217) | 45(652) |
Max Gas Inlet Pressure pA in bar (psi) | 1,500 (21,750) | 3.5 x pL | 20 x pL | 1,500 (21,750) |
Max Permitted Outlet Pressure pB in bar (psi) | 1,500 (21,750) | 1,500 (21,750) | 1,500 (21,750) | 1,500 (21,750) |
Formula To Calculate Gas Outlet Pressure pB | 75 x pL + pA | 75 x pL + 5 x pA | 75 x pL + 2.5 x pA | 150 x pL |
Displacement Volume In cm3 (ins3) | 50 (3.05) | 122(7.44) | 60 (3.66) | 25 (1.52) |
Air Drive pA In bar (psi) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) |
Air Consumption In L/min | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 400-1,980 (14.1– 69.9) | 600-2,400 (21.2-84.8) |
Gas Inlet Connection | 1/4 BSP | 1/2 BSP | 1/4 BSP | 1/4 BSP |
Gas Outlet Connection | 1/4 BSP | 1/4 BSP | 1/4 BSP | 1/4 BSP |
Air Drive Connection | 3/4 BSP | 3/4 BSP | 3/4 BSP | 3/4 BSP |
Net Weight (kg) | 18 | 19 | 19 | 20 |
Model | DLE 75-2-GG | DLE 15-75-2-GG | DLE 30-75-2-GG |
---|---|---|---|
Model | ![]() | ![]() | ![]() |
Pressure Ratio | 1:150 | 1:30 / 1:150 | 1:60 / 1:150 |
Max Compression Ratio | 1:20 | 1:100 | 1:50 |
Stage Ratio | - | 1:5 | 1:2.5 |
Min Gas Inlet Pressure pA in bar (psi) | 45 (652) | 7 (101) | 15 (217) |
Max Gas Inlet Pressure pA in bar (psi) | 1,500 (21,750) | 7 x pL | 40 x pL |
Max Permitted Outlet Pressure pB in bar (psi) | 1,500 (21,750) | 1,500 (21,750) | 1,500 (21,750) |
Formula To Calculate Gas Outlet Pressure pB | 150 X pL + pA | 150 X pL + 5 x pA | 150 X pL + 2.5 x pA |
Displacement Volume In cm3 (ins3) | 50 (3.05) | 122 (7.44) | 60 (3.66) |
Air Drive pA In bar (psi) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) |
Air Consumption In L/min | 600-2,400 (21.2-84.8) | 600-2,400 (21.2-84.8) | 600-2,400 (21.2-84.8) |
Gas Inlet Connection | 1/4 BSP | 1/2 BSP | 1/4 BSP |
Gas Outlet Connection | 1/4 BSP | 1/4 BSP | 1/4 BSP |
Air Drive Connection | 3/4 BSP | 3/4 BSP | 3/4 BSP |
Net Weight (kg) | 23 | 24 | 24 |
Model | DLE 30-75-2-25-GG | DLE 30-75-2-30-GG | DLE 30-75-3-36-GG |
---|---|---|---|
Model | ![]() | ![]() | ![]() |
Pressure Ratio | 1:60 / 1:150 | 1:60 / 1:150 | 1:60 / 1:150 |
Max Compression Ratio | 1:50 | 1:50 | 1:50 |
Stage Ratio | 1:2.5. | 1:2.5. | 1:2.5. |
Min Gas Inlet Pressure pA in bar (psi) | 15 (217) | 15 (217) | 15 (217) |
Max Gas Inlet Pressure pA in bar (psi) | 40 x pL | 40 x pL | 40 x pL |
Max Permitted Outlet Pressure pB in bar (psi) | 1,800 (25,000) | 2,100 (30,000) | 2,400 (36,000) |
Formula To Calculate Gas Outlet Pressure pB | 150 X pL + 2.5 x pA | 150 X pL + 2.5 x pA | 150 X pL + 2.5 x pA |
Displacement Volume In cm3 (ins3) | 60 (3.66) | 60 (3.66) | 60 (3.66) |
Air Drive pA In bar (psi) | 1-10 (14.5-145) | 1-10 (14.5-145) | 1-10 (14.5-145) |
Air Consumption In L/min | 600-2,400 (21.2-84.8) | 600-2,400 (21.2-84.8) | 600-2,400 (21.2-84.8) |
Gas Inlet Connection | 1/4 BSP | 1/4 BSP | 1/4 BSP |
Gas Outlet Connection | 1/4 BSP | 1/4 BSP | 1/4 BSP |
Air Drive Connection | 3/4 BSP | 3/4 BSP | 3/4 BSP |
Net Weight (kg) | 24 | 24 | 24 |