Gas Boosters to 40 bar (580psi)

Note : pA = Gas Inlet pressure / pL = Air drive pressure / pB = Gas Outlet pressure

Gas Boosters To 40 bar (580 psi)

ModelDLE 2-1-GGDLE 2-GGDLE 2-1-2-GGDLE 2-2-GGDLE 5-1-GG
Model
Pressure Ratio1:21:21:41:41:5
Max Compression Ratio1:101:101:101:101:15
Stage Ratio-----
Min Gas Inlet Pressure pA in bar (psi)00002 (29)
Max Gas Inlet Pressure pA in bar (psi)20 (290)40 (580)40 (580)40 (580)50 (725)
Max Permitted Outlet Pressure pB in bar (psi)20 (290)40 (580)40 (580)40 (580)50 (725)
Formula To Calculate Gas Outlet Pressure pB2 X pL2 X pL + pA4 X pL4 X pL + pA5 X pL
Displacement Volume In cm3 (ins3)922 (56.26)1,844 (112.52)922 (56.26)1,844 (112.53)373 (22.76)
Air Drive pA In bar (psi)1-101-101-10 (14.5-145)1-10 (14.5-145)1-10 (14.5-145)
Air Consumption In L/min400-1,980 (14.1– 69.9)400-1,980 (14.1– 69.9)600-2,400 (21.2-84.8)600-2,400 (21.2-84.8)400-1,980 (14.1– 69.9)
Gas Inlet Connection1/2 BSP1/2 BSP1/2 BSP1/2 BSP1/2 BSP
Gas Outlet Connection1/2 BSP1/2 BSP1/2 BSP1/2 BSP1/2 BSP
Air Drive Connection3/4 BSP3/4 BSP3/4 BSP3/4 BSP3/4 BSP
Net Weight (kg)1520222515